AbstractAbstract PDF
PURPOSE
The optimal method of fixation of symphysis pubis (SP) diastasis in pelvic ring injuries is still controversial. In this study, we investigated the radiological and the clinical results of a precontoured 4.5-mm symphysis pubis (SP) plate with tension band wiring (TBW) after an anterior pelvic injury in pelvic fractures.
METHODS
We treated 25 patients with traumatic SP diastasis by open reduction and internal fixation with plates and wires. We used a four-hole 4.5-mm precontoured SP plate with a tension band wiring.
RESULTS
Patients with a SP with TBW fixation achieved excellent or good results at final follow-up. Post-operative complications included two (8%) patients with metal work movement. The mean symphyseal width was smaller in 4.5 mm SP plate with TBW during 1-year follow up period.
CONCLUSION
A precontoured symphysis pubis plate (4.5 mm) with figure-of-eight fashion tension band wiring shows favorable radiological results, excellent or good clinical outcome, and a lower complication (hardware failure and revision surgery).
Summary

Citations

Citations to this article as recorded by  
  • Is there a clinical benefit of additional tension band wiring in plate fixation of the symphysis?
    Myung-sik Park, Sun-Jung Yoon, Seung-min Choi, Kwanghun Lee
    BMC Musculoskeletal Disorders.2017;[Epub]     CrossRef